Set port intrusion-trap-timer, Command mode, Description – Avaya P580 User Manual

Page 454: Syntax, Systems, Set port intrusion-trap-timer -22

Advertising
background image

Chapter 21

21-22

Command Reference Guide for the Avaya P580 and P882 Multiservice Switches, v6.1

set port intrusion-trap-timer

Command Mode

Global Configuration.

Description

Sets the time interval at which intrusion traps are generated. The default
setting for the intrusion trap timer is 1800 seconds (30 minutes). The valid
range for the timer is 60 to 1800 seconds.

Syntax

set port intrusion-trap-timer {<mod-num> | <mod-swport-range>}
[...,{<mod-num> | <mod-swport-range>}] <intrusion-trap-timer-value>

Systems

P550R, P580, P880, and P882.

Table 21-20. Parameters, Keywords, Arguments

Name

Definition

<mod-num>

Specifies the number of the module.

<mod-swport-
range>

Specifies a range of switch ports.

<intrusion-trap-
timer-value>

Time interval at which intrusion traps are generated.

The default setting for the intrusion trap timer is 1800
seconds (30 minutes). The valid range for the timer is 60 to
1800 seconds.

Advertising