Clear utilization high-threshold, Command mode, Description – Avaya P580 User Manual

Page 622: Syntax, Systems, Clear utilization high-threshold -6

Advertising
background image

Chapter 30

30-6

Command Reference Guide for the Avaya P580 and P882 Multiservice Switches, v6.1

clear utilization high-threshold

Command Mode

Global Configuration.

Description

Resets the high utilization threshold to its default setting of 95 percent. You
can reset the high utilization threshold for the CPU, forwarding engines on
80-series media modules, or forwarding engine on the supervisor module.

For the switch to generate events when the high-utilization threshold is
exceeded, event logging must be enabled for utilization monitoring. To
enable event logging for utilization monitoring, use the

set utilization

threshold-event

command.

Syntax

clear utilization high-threshold {cpu | FIRE | FORE}

Systems

P580 and P882.

Table 30-3. Keywords, Arguments, and Options

Name

Definition

cpu

Resets the high threshold for CPU utilization.

100% CPU utilization is the total capacity of
the supervisor module to forward slow path
traffic. When 100% utilization is reached, the
performance of the switch may degrade.

FIRE

Resets the high threshold for utilization of the
forwarding engines on 80-series media
modules.

100% FIRE utilization is the total capacity of
the forwarding engines on 80-series media
modules to forward in band traffic. When
100% utilization is reached, the performance
of the switch may degrade.

FORE

Resets the high threshold for utilization of the
forwarding engine on the supervisor module.

100% FORE utilization is the total capacity of
the supervisor module to forward out-of-band
traffic. When 100% utilization is reached, the
performance of the switch may degrade.