Wiring diagram, G1014, 1 of 2) – LiftMaster BG770 Industrial-Duty Single Arm Barrier Gate Operator User Manual

Page 21: Control wiring type l2 field wiring

Advertising
background image

21

08/28/00

NOTES:

1) TRANSFORMER PRIMARY VOLTAGE SAME AS OPERATOR LINE VOLTAGE
24V SECONDARY.

2) RELAY COIL VOLTAGE SAME AS OPERATOR LINE VOLTAGE.

3) WE RECOMMEND USING A DEDICATED CIRCUIT BREAKER FOR EACH OPERATOR.

APPLICATIONS:

MODEL TYPES:

DRAWING NUMBER:

DATE:

REVISION:

ECN:

HORSEPOWER:

VOLTAGE/PHASE:

CONTROL WIRING TYPE L2

FIELD WIRING

1/2

115/230V, 60Hz, 1 PHASE ONLY

01-G1014

F-3/20/08

BG770, BG790

(GN)

08-7165

115V

ACCESSORIES

(W)

(BK)

WIRING DIAGRAM

MOTOR CONNECTION SAME
AS INCOMING POWER.
FOR BG770, INTERCHANGE
GREEN AND RED WIRES

115V MOTOR
CONNECTION

230V MOTOR
CONNECTION

230V ONLY

(GN)

(BK)

(W)

(R)

Y

W

2

4

BR

BR

BR

BR

8

BK

5

OR

BL

3

1

W
4

R

8

BK

Y

BL

2

3

5

OR

1

(R)

(W)

(BK)

(GN)

6

5

OP

OP

1

2

CL

(OR)

CL

CL

3

3

4

4

OP

1

2

5

6

(BL)

FUSE 3.2A

115V ONLY

115V ONLY

(BK)

(BK)

(BK)

(BK)

(BK)

0/L

IR

L2

L1

H1

H2

7

IR

IR

1

5

14

J4–4

J4–6

10

2

J3

J4

14

13

13

J3–6

J3–4

3

SEE NOTE 2

SEE NOTE 1

(W)

(Y)

(YEL)

(PUR)

(OR)

(GY)

(BL)

(GN)

(OPTIONAL)

(GN)

(R)

(OR)

(BL)

(BR)

OP

R2

R1

6

(W)

(R)

CL

(R)

(OR)

(GY)

(W)

(W)

(OR)

CLOSE

HOLD OPEN

LOOP–PRESENCE

REMOVE JUMPER WHEN
TIMER IS ADDED

ADD JUMPER WHEN USING CLOSE BUTTON
DO NOT USE WITH HOLD OPEN LOOP

TIMER

(OPTIONAL)

(OR)

(OR)

(OR)

(GN)

(BK)

(PUR)

(R)

P1

P2

P3

P4

J3–9

J3–10

J4–9

J4–10

(R)

(BK)

(BK)

(BL)

J3–7

J4–7

J4–8

J3–8

24V HOLD

OPEN LOOP

(OPTIONAL EQUIPMENT)

24V OPEN

LOOP

HOLD OPEN LOOP

LOOP WIRES

(OPTIONAL)

OPEN LOOP

LOOP WIRES

(OPTIONAL)

C

NO

CLOSE L/S

(BR)

R2

R1

R1

R2

8

9

R1

OP

(YEL)

(GN)

AUTO/MANUAL

OPEN

OPEN LOOP–PRESENCE

SENSING

EDGE

(OPTIONAL)

1) REMOVE JUMPER WHEN TIMER TO

CLOSE IS USED.

2) REMOVE JUMPER TO CAUSE GATE

ARM TO CLOSE IMMEDIATELY UNLESS

HOLD OPEN LOOP IS ACTIVATED.

24V SEC.

(W)

(W)

(W)

1 PHASE
INCOMING LINE
(SEE NOTE 3)

24V COIL

24V COIL

24V COIL

24V COIL

CL

OPEN L/S

NO

C

AUX.

CLOSE L/S

(BRN)

(GY)

(GY)

(BRN)

TERMINAL BLOCK

WIRE CONNECTION FOR STANDARD CONTROL DEVICES

WIRE CONNECTION FOR OPTIONAL DEVICES

WIRE CONNECTION FOR 230V UNITS ONLY

IS CONNECTOR FOR 24V OPEN LOOP DETECTOR

IS CONNECTOR FOR 24V HOLD OPEN LOOP DETECTOR

To protect against fire and electrocution:

• DISCONNECT power BEFORE installing

or servicing operator.

• Replace ONLY with fuse of same type

of rating. Fuse 3.2A, 3AG, 250V, SLO-BLO

4) BROWN WIRES INSIDE MOTOR NOT USED, SHOULD BE WIRE NUTTED.

O/L SEE
NOTE 4

O/L SEE
NOTE 4

(1 of 2)