Preparations, Carton inventory, Site preparation – LiftMaster BG770 Industrial-Duty Single Arm Barrier Gate Operator User Manual

Page 5: Operator preparation, Warning

Advertising
background image

5

CARTON INVENTORY

1. Unpack the carton, checking for possible damage during

shipping. The arm (when provided) is packed separately.
Damage claims MUST be filed with the freight carrier.

2. Check that the nameplate data (inside service cover) accurately

matches the operator that was ordered.

3. Verify that the following parts are included with the standard

unit.

SITE PREPARATION

1. Be sure that selected gate location has required clearance for

arm movement (and counterweights on model BG790). Refer to
the dimensional drawings on page 3.

2. Run electrical power to the site according to local electrical

codes (Figure 1). See chart on page 7 for correct wire size and
length of run. If the wire gauge is too high (wire too small) or
the run is too long, the gate may not run properly or may not
run at all. Damage to components may result.

IMPORTANT NOTE: Be sure that the available power is the proper
voltage, phase, frequency, and amperage to supply the gate.
Refer to gate nameplate located inside the service cover.

3. Select locations for control equipment and run any control

wiring that may be needed (such as loop wires, card readers,
ticket spitters, pushbuttons, etc.).

OPERATOR PREPARATION

1. Remove the wood base from the unit and discard.

2. Locate the keys for the access panel (taped to the arm

mounting flange) and remove.

3. Open the side access panel and check the position of the power

ON/OFF switch.

4. Open the cover of the electrical cabinet and be sure that the

AUTO/MANUAL switch is in the “AUTO” position.

5. OPTIONAL CONTROL EQUIPMENT: If loop detectors, radio

controls, or other control equipment will be added at the site,
do so now. Refer to the instructions in this manual for
installation of factory-provided optional open and/or hold open
loop detectors and for connection of factory-provided optional
radio controls (see Optional Accessories on page 12).

P R E P A R A T I O N S

MODEL BG770 PACKING LIST

MODEL BG790 PACKING LIST

PART NUMBER DESCRIPTION

QTY

02-102

Open/Close Push Button

1

07-8007

Gate Arm Hub

1

10-8007M

Gate Bracket

1

80-G0187

Key, 1/2 x 1/2 x 1-3/8

1

82-NH38-06

Cone Point Set Screw, 3/8-16 x 3/8

2

82-HN50-25

Hex Bolt, 1/2-13 x 2-1/4

4

82-RH-50

Hex Nut, 1/2-13

4

85-LS-50

Split Lock Washer, 1/2

4

01-G0674

Owner’s Manual

1

PART NUMBER DESCRIPTION

QTY

02-102

Open/Close Push Button

1

07-8007

Arm Hub

2

10-8055

Counter Weight Clamp

2

80-G0135

Threaded Rod, 3/8-16 x 18

2

80-G0187

Key, 1/2 x 1/2 x 1-3/8

2

82-HN50-25

Hex Head Bolt, 1/2-13 x 2-1/4

12

82-HN50-28

Hex Head Bolt, 1/2-13 x 3

2

82-NH38-06

Cone Point Set Screw, 3/8-16 x 3/8

4

84-RH-50

Hex Nut, 1/2-13

14

84-WH-38

Serrated Flange Nut, 3/8-16

8

85-FW-38

Flat Washer, 3/8

8

85-FW-50

Flat Washer, 1/2

8

85-LS-50

Split Lock Washer, 1/2

16

01-G0674

Owner’s Manual

1

To reduce the risk of SEVERE INJURY or DEATH, disconnect
power BEFORE performing ANY adjustments.

WARNING

Figure 1

AUTO/MANUAL switch should
be in the “AUTO” position.

NOTE: Install line power here. Do not
install line power in panel shown below.
Power switch should be in the OFF position.

Advertising