OPERATION

Prewired terminal strip accepts field connection of any access
control device with normally open (N.O.) output contact (most
access control equipment) and when required, a separate
OPEN/CLOSE pushbutton (provided).

Plug-in connectors are included for addition of a loop detector
to open and/or a loop detector to hold open (not provided).
Activation of access device open button, or loop detector to
open will raise gate. Gate will lower automatically unless hold
open loop detector is activated or unless CLOSE button wiring
has been made, in which case gate will remain open until
CLOSE button is pushed.

An optional timer will extend the time that the gate remains
open. AUTO/MANUAL switch holds arm in vertical position.

ENCLOSURE

Weatherproof, heavy gauge, pregalvanized steel, powdercoat
finish, top and side access covers with key lock.

MECHANICAL

SPEED REDUCTION

Wormgear-in-oil-bath, 60:1

ARM TYPE

MODEL BG770: One piece type to 15'

MODEL BG790: Counterweighted wishbone type to 24'

ARM SPEED

MODEL BG770: Opens in 4 seconds

MODEL BG790: Opens in 11 seconds

LUBRICATION

Permanently lubricated bearings in motor. Low temperature
gear oil normally never needs replacement. Gear oil is
Mobil SHC 630 or equivalent.

MOUNTING

Pad mount

S P E C I F I C A T I O N S

MOTOR

Squirrel cage induction type (3 phase) or capacitor start
induction type (1 phase), continuous duty, 1725 RPM.
Horsepower is designated by second suffix of operator part
number.

-50; 1/2 Horsepower

POWER

Line voltage is designated by third suffix of gate part number.
For amp draw, see motor nameplate.

-11; 115Vac, 1 Phase, 60Hz
-21; 230Vac, 1 Phase, 60Hz
-81; 208Vac, 1 Phase, 60Hz
-83; 208Vac, 3 Phase, 60Hz
-23; 230Vac, 3 Phase. 60Hz
-43; 460Vac, 3 Phase, 60Hz
-53; 575Vac, 3 Phase, 60Hz

ELECTRICAL

OVERLOAD PROTECTION

Automatic reset (3 phase operators) or manual reset (1 phase
operators) thermal overload.

ELECTRICAL BOX

NEMA 1 general purpose painted steel enclosure, contains all
motor control equipment. Enclosure removable from operator.

CONTROL CIRCUIT

Class II, 24Vac

LIMIT SWITCHES

Adjustable, driven limit switches, operate in class II circuit. Not
affected by removal of motor.

POWER ON/OFF SWITCH

Enclosed toggle switch, HP rated.

Model BG770

Model BG790

Typical
Installation

Typical
Installation

DIMENSIONS

DIMENSIONS

Up to 24'

Up to 15'

17"

17"

17"

17"

22"

44"

44"

35"

35"

Counterweighted
Wishbone Arm