Teledyne LeCroy Merlin Mobile - Users Manual User Manual

Page 99

Advertising
background image

91

Merlin Mobile User’s Manual

CATC

SW Version 2.0

Step 2

Click Change Counter Value

You see the Input Counter Value menu

Step 3

Enter an input value to tell the Analyzer how many times this
event must occur before triggering the end of a recording

Step 4

Click OK.

Filter Out/In Blue Dot Menu

The Filter Out/In button toggles between "Filter Out" and "Filter In".

Filter In records ONLY those packets related to the specified event.

Filter Out records all packets EXCEPT those related to the specified event.

To filter an event in or out of a recording,

Step 1

Click the blue dot on Filter Out. (Note: the button may say
Filter In depending on the last action specified.)

You see the Filter Out/In menu:

Use this menu to toggle the selection between Filter Out and Filter In.

Step 2

Select "Filter In".

The button changes to read "Filter In".

Blue Dot Menus for the Event Buttons

The Errors button and the first Headers button (marked "Hdr1") have the
same Blue Dot menus. These menus allow Merlin Mobile to trigger
external output.

To enable or disable external trigger output,

Step 1

Click the Blue Dot on an Event button such as Hdr1 or Errors.

Advertising