Using the InfiniBand Compliance Test Suite

Test Description

74

CATC IBTrainer InfiniBand Exerciser, August 2002

Test Description

The tests described here are based on InfiniBand Architecture

Specification Release 1.0.a

available at http://www.infinibandta.org/.

Some of them are implementations of already existing Test Descriptions

from InfiniBand Architecture Test Specification, version 0.8 from May

2001, available from the InfiniBand TA. These can be recognized by a

leading TD_ in the name.

Available Tests

In this section, all tests are descibed by the following items:

• Name

This is the name of the function that contains the test. A prefix TD_

indicates that this is the implementation of a Test Description.

• Description

Short description of the test.

• Topology

All tests described here need a Simple topology. That means that the

DUT must be connected to the IBTrainer.

• Initial link state

The following initial link states are used (Active or LinkDown)

• Assertions

Assertions covered by the test.

• DUT

Specifies which DUT the test is valid for.

• Prerequisites

For most tests, the SanityCheck must be passed before the tests can

be carried out..

The SanityCheck is performed to ensure a valid InfiniBand

connection. It consists of sending the SubnDirectGet(PortInfo) SMP to

the DUT and waits 1000 ms for a response. This is repeated three

times. If no response is detected, the check fails.

• Test procedure

Descibes what happens during the test execution.