Using the InfiniBand Compliance Test Suite

Test Description

92

CATC IBTrainer InfiniBand Exerciser, August 2002

EUI-64 GUID Assigned by Manufacturer

v1c04-001

Four Running Disparity Errors in a
Sequence

v2c05-013

Item

Value

Name

v1c04-001

Description

The ‘GUID’ field in the NodeInfo of the DUT is tested.

Topology

Simple

Initial link state

Active

Assertions

v1c04-001

Prerequisites

None

Test procedure

Requests the GUID of the DUT and checks it.
The 24-bit company ID of the GUID is expected to be
non-zero.

Item

Value

Name

v2c05-013

Description

The test is used to ensure that the DUT does not re-
spond to a packet where the symbol ‘EGP’ is re-
placed by 4 running disparity errors within 13
symbols.

Topology

Simple

Initial link state

Active

Assertions

v2c05-013

Prerequisites

SanityCheck

Test procedure

A SubnDirectGet(PortInfo) packet is sent to the DUT.
Instead of the symbol "EGP", 4 running disparity er-
rors spread out over 13 symbols are inserted.

No response is expected.