Using the InfiniBand Compliance Test Suite
Test Description
92
CATC IBTrainer InfiniBand Exerciser, August 2002
EUI-64 GUID Assigned by Manufacturer
v1c04-001
Four Running Disparity Errors in a
Sequence
v2c05-013
Item
Value
Name
v1c04-001
Description
The ‘GUID’ field in the NodeInfo of the DUT is tested.
Topology
Simple
Initial link state
Active
Assertions
v1c04-001
Prerequisites
None
Test procedure
Requests the GUID of the DUT and checks it.
The 24-bit company ID of the GUID is expected to be
non-zero.
Item
Value
Name
v2c05-013
Description
The test is used to ensure that the DUT does not re-
spond to a packet where the symbol ‘EGP’ is re-
placed by 4 running disparity errors within 13
symbols.
Topology
Simple
Initial link state
Active
Assertions
v2c05-013
Prerequisites
SanityCheck
Test procedure
A SubnDirectGet(PortInfo) packet is sent to the DUT.
Instead of the symbol "EGP", 4 running disparity er-
rors spread out over 13 symbols are inserted.
No response is expected.