116

Merlin Protocol Analyzer User’s Manual

CATC

Version 1.7

Table 5: External Interface Breakout Board: Pin Description

You can use pins 6-10 on the Breakout Board as Trigger Inputs for the Analyzer
from your hardware. If you hook up any of these pins, you must check the
corresponding Trigger Input number in this Recording Options Event Group to
enable it as a Trigger.

You can enable or disable Trigger Inputs 0 through 4 from the Breakout Board.
These inputs may also be set as Active-Low or Active-High signals.

Note

When you use the Active-High setting, the Analyzer internally pulls up the
Trigger input signals on the Breakout Board. Your External Trigger source
should drive the input signal low before starting to record or the Analyzer
immediately detects a Trigger Event because of the signal pull-ups.

Pin

Signal Description

1

GND

Signal Ground

2

GND

Signal Ground

3

+5V

5V DC source, limited internally to 500mA (polyswitch fuse)

4

TRIGGER OUT

Active-low TTL output

5

SPARE

Not connected

6

IN 0

Trigger/signal TTL input—programmable as active high or low

7

IN 1

Trigger/signal TTL input—programmable as active high or low

8

IN 2

Trigger/signal TTL input—programmable as active high or low

9

IN 3

Trigger/signal TTL input—programmable as active high or low

10

IN 4

Trigger/signal TTL input—programmable as active high or low

11

TRIGGER IN

Trigger input—programmable as active high or low

12

RESERVED 1

Reserved for future enhancement

13

RESERVED 2

Reserved for future enhancement

14

OUT 0

Signal TTL output—programmable as pulse high/low or toggle

15

OUT 1

Signal TTL output—programmable as pulse high/low or toggle

16

OUT 2

Signal TTL output—programmable as pulse high/low or toggle

17

OUT 3

Signal TTL output—programmable as pulse high/low or toggle

18

OUT 4

Signal TTL output—programmable as pulse high/low or toggle

19

OUT 5

Signal TTL output—programmable as pulse high/low or toggle

20

GATED VP

USB D+ signal—output after buffering

21

GATED VM

USB D- signal—output after buffering

22

GND

Signal Ground

23

GND

Signal Ground

BP

1

CURRENT MEASURE
+

Banana plug for optionally measuring the current of the USB Device
connected to the Record & Generate port of the Analyzer

BP

2

CURRENT MEASURE

Banana plug for optionally measuring the current of the USB Device
connected to the Record & Generate port of the Analyzer

n/a

9 by 31 plated through
holes

Prototype rework area; Top row connected to +5V; Bottom row
connected to GND; Remaining holes are not connected