UWBTracer/Trainer User Manual

Chapter 15: Creating and Editing Generation Files

LeCroy Corporation

253

Declarations: Contains all the %include statements of all the default definition
files, along with global settings values. You can %include your own definition files.
This element does not link to the rest of the scenario but is required.

Begin: Is the first element in a scenario diagram. There is one and only one of these
in a scenario.

End: Terminates the scenario. One and only one is required.

Timer Elements

The timer elements are Start Timer, Stop Timer, and Reset Timer.

For the Start Timer element, you can enter:

Timeout Value: Specifies the timer timeout in microseconds. Timeout must
be set to a non-zero value to register a Timer condition. Default is
UNDEFINED.

AutoReset: Select ON to automatically reset the timer. Select OFF to not
reset the timer. Default is OFF.

TimeVar Index: Enter the index name of the Time variable in which to keep
the condition timestamp when it is triggered or leave UNDEFINED. Default is
UNDEFINED (timestamp is not saved).

The Stop Timer element has no specific options.

The Reset Timer element has no specific options.

Wait Elements

The wait elements are Wait Condition and Wait For SuperFrame.

For the Wait Condition element, first select one or more conditions that you previously
entered. TIMER can be a condition. Then require Any or All of the selected conditions.

The Wait For SuperFrame element has no specific options.