Settings Element

For the Settings element, you can enter or select:

UwbTxPower: Enter an integer to indicate the UWB transmitter power in
watts. Possible values are 0 (no transmitting) to 15 (max level). Default value
is 0.

UwbTxChannel: Select a UWB transmitter channel from the list to specify the
wireless channel that UWBTrainer uses to transmit WiMedia traffic. The
setting value for channel mapping includes Band Group (6 bits) and TF Code
(3 bits) as specified in the WiMedia PHY Specification. Default value is AUTO
(UWBTrainer uses the currently specified channel.)

UwbRxChannel: Select a UWB receiver channel from the list to specify the
wireless channel that UWBTrainer uses to receive WiMedia traffic. The setting
value for channel mapping includes Band Group (6 bits) and TF Code (3 bits)
as specified in the WiMedia PHY Specification. Default value is AUTO
(UWBTrainer uses the currently specified channel.)

SuperFrame Period: Enter an integer to indicate the SuperFrame period in
microseconds. Possible values are 0 to 0xFFFFFF. Default value 0.

FrameDelay: Enter an integer to specify the default delay in nanoseconds
between transmitted frames. Default value: 0 (Frames are transmitted without
delay.) Note: This value can be overridden by the Delay parameter in a Send
Frame instruction.

AddMissingFields: Select On to instruct the script parser to add any missing
frame template fields for Send Frame instructions. Missing TX frame template
fields might include FCS. Missing RX frame template fields might include FCS
+Rx packet end report fields (such as RSSI and LQI), which are used in
conditions. Select OFF to not add fields. Select UNDEFINED to turn off this
feature. Default value is ON.

Recording Elements

The recording elements are Start Trace, Stop Trace, Tx Sleep, and Trigger.

For the Start Trace element, enter the Recorded Options File Path and Name and the
Trace File Path and Name. You can select to KeepOldTrace.

For the Stop Trace element, enter No (no WaitForUpload) or Yes (WaitForUpload).

For the Tx Sleep element, enter a Time in microseconds (default = 0) and (optionally) a
Fine Time Adjustment in nanoseconds (default = 0).

The Trigger element has no specific options.

Connector Element

The Connector element is used only to allow a link to change direction.

Advertising