9) vref tests, D1) demo of all tests, Qphy-ddr3 variables – Teledyne LeCroy QPHY-DDR3 User Manual

Page 29: General variables, Dut speed grade in mt/s, Qphy-ddr3 software option

Advertising
background image

QPHY-DDR3 Software Option

917717 Rev C

29

• tIH (base + derated)
• tIPW

7) CKdiff-DQse-DQSp-DQsn (4 probes test, each DQS signal probed single ended)

• VSEH(ac)
• VSEL(ac)
• VIX(ac)
• AC Overshoot Peak Amplitude
• AC Overshoot Area above VDDQ
• AC Undershoot Peak Amplitude
• AC Undershoot Area below VSSQ
• SlewR
• SlewF

8) CKp-CKn-DQse-DQSdiff (4 probe test, each CK signal is probed single ended)

• VSEH(ac)
• VSEL(ac)
• AC Overshoot Peak Amplitude
• AC Overshoot Area above VDDQ
• AC Undershoot Peak Amplitude
• AC Undershoot Area below VSSQ
• SlewR
• SlewF

9) Vref tests

• Vref(dc)

D1) Demo of All Tests

This configuration uses the saved waveforms found in the D:\Waveforms\DDR3 folder and run all of the
tests. All of the variables are set to their defaults except Use Stored Waveforms is set to Yes and Use
Stored Trace for Speed Grade
is set to Yes. The limit set in use is DDR3-1333. All supported tests are
run.

QPHY-DDR3 VARIABLES

General Variables

The following variables are used by all configurations. They can be used in conjunction with the test
selection and limit set selection to create custom configurations.

DUT Speed Grade in MT/s

Transfer speed of the DUT. Used to set the oscilloscope timebase and sampling rate, see Clock Period
Per Screen Division
variable for more explanation. Choose between: 800, 1066, 1333, 1600 MT/s or
custom. Default is 1333MT/s.

Advertising