Vanguard PCI-600 User Manual

Page 6

Advertising
background image

PCI-600 USER’S MANUAL

REV 2

3

1.2

PCI-600 Technical Specifications

Table 1. PCI-600 Technical Specifications

TYPE 100 - 600 Amp current source

PHYSICAL SPECIFICATIONS Dimensions: 17”W x 12.5”H x 10.5”D (42.6 cm x 32.0 cm x 27.0 cm);

Weight: 46 lbs (21 kg)

INPUT POWER

100 – 120 Vac or 200 – 240 Vac (factory pre-set), 50/60 Hz

INTERNAL METER RANGE

100 mA – 1000 A; Accuracy: 1% of reading ±20 mA

MEASUREMENT METHOD

Isolated CT

EXTERNAL METER RANGE

10 mA – 10 A; Accuracy: 1% of reading, ±2mA

MEASUREMENT METHOD

Isolated CT

TIMER READING RANGE

1ms – 2 hours; Accuracy: 0.1% of reading ±1ms

TIMER STOP INPUTS

Voltage input (24V – 300V, DC or peak AC), dry contact input, or removal
of primary current

DISPLAY

Back-lit LCD Screen (20 characters by 4 lines); viewable in bright sunlight
and low-light levels

COMPUTER INTERFACE

RS-232C port for factory calibration and diagnostics

SAFETY

Designed to meet IEC61010 (1995), UL61010A-1, CSA-C22.2 standards

ENVIRONMENT

Operating: -10˚C to 50˚ C (15˚F to +122˚ F); Storage: -30˚ C to 70˚ C (-
22˚F to +158˚ F)

CABLES

10-foot #1/0 AWG test leads, power cord, ground cable

OPTIONS

Transportation case

WARRANTY

One year on parts and labor

NOTE

The above specifications are valid at nominal operating voltage and at a
temperature of 25

°C (77°F). Specifications may change without prior notice.

Advertising