Troubleshooting

Fault

Reason

Remedy

Not enough voltage

Check the motor potential at work. The voltage may fluctuate

in 10%

Motor do not work

Check the motor and electric circuit

Motor turn reverse

Change two phases in three freely

Motor lack phase (motor can not

turn and make noise)

Check the fuse and wire connection

restrict-speed valve has been open

Check the restrict-speed valve with voltmeter (the switch

“down” must be loosed). If voltage do not exist, check

the electric circuit. Otherwise, clean the restrict-speed

valve or change it.

Not enough pressure

Regulate the overflow valve under the full load

Not enough hydraulic oil

Fill the oil-tank with hydraulic oil

Filter tip has been blocked up

Clean the filter tip

There is air in oil pipe

Check the oil pipe and joint. Twist the joint firmly or change

it if necessary

The platform

can not rise

Overload

Reduce the load

One-direction valve leak oil

Clean the one-direction valve or change it if necessary

Restrict-speed valve has not been

sealed

Check whether voltage exist on the restrict-speed valve. If

exist, clean the restrict-speed valve or change it.

Platform

self-descend

Cylinder leak oil

Change the seal unit in the cylinder or change the cylinder

Restrict-speed valve lose efficacy

Check whether voltage exist on the restrict-speed valve. If

exist, clean the restrict-speed valve or change it.

Platform can not

descend

Restrict-speed valve dislocation

Regulate the restrict-speed valve, if regulation has not use ,

change the valve