Battery replacement – Vestil S-CB-118 User Manual

Page 23

Advertising
background image

23

Filename: Changing Batteries in S-62 Stacker

VESTIL MFG. CO.

Model: S-62/AA/FF/FA

Instructions for Changing the Batteries, estimated time, 15 min.

READ ALL INSTRUCTIONS BEFORE PROCEEDING!

Only qualified personnel should work on this equipment!

Lock out all potential energy sources before attempting this installation; turn off the
unit and remove the key.

Warning!

!

Working with or near lead acid batteries is dangerous. Batteries contain
sulfuric acid and produce explosive gases. A battery explosion could result in
loss of eyesight or serious burns.

!

Do not smoke or allow a spark or flame near batteries. Charge batteries in
locations which are clean, dry, and well-ventilated. Do not lay tools or
anything metallic on top of any battery. All repairs to a battery must be
made by experienced and qualified personnel.

!

When working with batteries, remove personal items such as rings, bracelets,
necklaces, and watches. Batteries can produce enough energy to weld
jewelry to metal, causing a severe burn.

!

Always have fresh water and soap nearby in case battery acid contacts skin,
clothing, or eyes.

!

Operating the battery with a low battery voltage can cause premature motor
contact failure.

!

Do not expose the lift or charger to rain or adverse conditions.

!

Replace defective cords or wires immediately.

!

Check the battery’s water level frequently if this applies to your battery type.

!

Make sure the battery charger is unplugged from 115vac source.

Battery Charger Operating Instructions

Plug the charger into a standard 115V receptacle. If an extension cord must be

used, keep it as short and as large as possible. A small cord will decrease the output
of the charger due to the voltage drop in the line. This will increase the charging time.
It can also cause the 115V cord to overheat.

When properly connected, the charge LED will indicate the status of charge current
flowing to the battery, as follows: Power LED is always green when charger is plugged
in. The status light is as follows:

Red only – the charger is providing full output to the battery.

Yellow – the charger is “topping off” the battery.

Green – the charger is providing a “float,” or maintenance, charge.

Remember to unplug the charger before moving the equipment. Failure to do so could cause damage to cords, receptacles