Warner Electric ARC 2000 User Manual

Page 8

Advertising
background image

8 Warner Electric • 800-825-9050

P-2016 • ARC

Press bearing out of housing using FIX-0002 and an
arbor press. See FIgure 29.

Figure 29

Turn housing over. Press new bearing in housing
using FIX-0002 and an arbor press. See Figure 30.

Figure 30

Separate magnet stack and clean all magnets –
replace as required. Use an alcohol based cleaning
solvent to clean the black driver magnets. Do not
use anything abrasive when wiping the black driver
magnets. Use a Scotch Brite deburr wheel to polish
the hysteresis magnet. See Figure 32.

Figure 32

Put in new seal. See Figure 31.

Figure 31

FIX-0002

FIX-0002

To replace the magnet on end cap, break the
magnet with a hammer. Remove broken magnet
pieces and old screws. Install new magnet and
new screws. Epoxy magnet holes with epoxy
packet from rebuild kit. Make sure epoxy does
not build up on surface of magnet more than
.010” (0.25mm). See epoxy instructions below
(Figure 34)

Figure 33

Install magnet plate into housing. Line up any
three holes and insert screws. See Figure 35.

Figure 35

Tighten the three socket head cap screws with a
9/64” 3mm hex wrench. See Figure 36

Figure 36

Figure 34

Advertising