Warner Electric CBC-160-2N User Manual

Page 3

Advertising
background image

3

Warner Electric • 800-825-9050

P-239-36 • 819-0450

Installation

To avoid injury, always make

certain all power is off before attempting

to install this control or any electrical

equipment.

A . CBC-160-1N Wiring, AC Input

1 . If using a single source 120VAC input not

from an AC motor, connect the black/red
wire to the hot side of the 120VAC power
through the switch and fuse . Connect
the white wire to the neutral side of the
AC power .

Refer to (Figure 1) for wiring

connections .

2 . If wiring to a motor for operation wih

an electrically released brake, refer to
(Figures 2 and 3) for correct wiring for
either 120/230VAC motor connections .

B . CBC-160-2N Wiring, AC Input

1 . If using a single source 230VAC input not

from an AC motor, connect the black/red
wire to the one side of the 230VAC line
through the switch end fuse . Connect the
white wire to the other 230VAC line .

NOTE: On 230VAC single phase,

connection from either line to neutral will
produce only 120VAC .

Refer to (Figure 1) for wiring connections .

2 . If wiring to a motor for operation with

an electrically released brake, refer to
(Figures 4 and 5) for correct wiring for
either 230/480VAC motor connections .

C . Brake to Control wiring . Connect the

brake (or clutch) wires to the solid red wire
(positive) and red with white striped wire
(negative) of the control .

D . The control is factory adjusted for 80 VDC .

For Electro Module Fail Safe Motor Brakes
adjust the potentiometer as needed for
optimal brake release when power is applied
to the control . For all other types of brakes
and clutches adjust the potentiometer for the
required torque in your application .

This is a floating-type control

and is not referenced to AC ground. Under

no circumstances should any of the output

wire leads be connected to earth or chassis

ground or shorted together, as the unit will

be destroyed.

HOT

fuse switch

Black/red

user furnished

White

CBC-160-1N

or

CBC-160-2N

Red (+)

Red/white

90 VDC

Clutch or Brake

Neutral

CBC-160-1N:

120 VAC

CBC-160-2N:

208-240 VAC

Wiring

Figure 1

Advertising