Cbc-160-2n, Cbc-160-1n, Connection diagrams – Warner Electric CBC-160-2N User Manual

Page 4

Advertising
background image

4

Warner Electric • 800-825-9050

P-239-36 • 819-0450

WYE Connected Motor

T7 T8 T9

T1 T2 T3

T4 T5 T6

480 VAC

Red +

Red/white

CBC-160-2N

Black/red

White

240 VAC

90 VDC

BRAKE

(Motor Terminals)

+

-

0

100

50

T7 T8 T9

T1 T2 T3

T4 T5 T6

230 VAC

Red +

Red/white

CBC-160-2N

Black/red

White

230 VAC

90 VDC

BRAKE

(Motor Terminals)

+

-

0

100

50

3 4

1 2

8 5

120 VAC Motor

Red +

Red/white

CBC-160-1N

Black/red

White

120 VAC

90 VDC

BRAKE

+

-

0

100

50

2 5

1 4

3 8

230 VAC Motor

Red +

Red/white

CBC-160-1N

Black/red

White

120 VAC

90 VDC

BRAKE

+

-

NOTE: If motor direction needs to be reversed, wires 5 & 8

are reversed. Corrections to CBC-160-1N do not change.

0

100

50

Figure 2

Figure 3

Connection Diagrams

Figure 4

Advertising