System start-up – Warner Electric CBC-750 User Manual

Page 11

Advertising
background image

11

Warner Electric • 800-825-9050

819-0494

System Start-Up

Do not apply power to the control

at this time.

1.

Double check all control and magnet

wiring connections to insure that they are
exactly in accordance with the appropriate
wiring diagrams.

2.

Turn the Channel 1 and Channel 2 torque

adjust potentiometers fully counterclock-
wise, their minimum output settings.

3.

For future reference, record the model
numbers and voltages of the clutch/brake

magnets and /or fields in the blank spaces
below:

Channel 1___________ Voltage___________
Channel 2___________ Voltage___________

4.

Refer to dip switch selection charts below

and Figure 8, facing page. Set dip switches

SW7 and SW8 for the proper range settings
based on magnet and field sizes. Switch SW7
sets the current ranges for Channel 1 and
switch SW8 sets the range for
Channel 2.

CBC-750

Current Range Selections

For Dip Switches SW7 and SW8

6 Volt Table

Models

Range #

SF/PB 120, 170, 250, 400

1

EC/EB 375, 475

2

EM 50, 180

PB/PC 500, 1225, 1525

3

EB 1225
EM 210
AT 25

PB/PC 825, 1000

4

PB 650
EC/EB 650, 825, 1000

6 Volt Table

Models

Range #

EC 650, 1000

4

SF 650, 1000
AT 55

SF 500, 825 Brg, 1000, 1525

5

EC 825, 1225
AT 115

24 Volt Table

Models

Range #

SF/PB 120, 170, 250, 400

1

EC/EB 375, 475

2

EM 4, 5

2

PC/PB 500, 825, 1225

3

SF 825
EC/EB 825
EB 1225
AT 25

PC/PB 1000, 1525

4

PB 650
EC/EB 650, 1000
SF 650, 1225
EM 6
AT 55

SF 500, 1000, 1225, 1525

5

90 Volt Table

Models

Range #

SF/PB 120, 170, 250, 400

1

EC/EB 375, 475

2

EM 50 , 180

PC/PB 1225, 1525

3

PB 650
SF 825, 1225
EB 650, 1225
EM 210
AT25

Advertising