Figure 9 - input/output relationships – Warner Electric CBC-750 User Manual

Page 12

Advertising
background image

12

Warner Electric • 800-825-9050

819-0494

90 Volt Table (Cont'd)

Models

Range #

PC/PB500, 1000

4

EC/EB 1000
SF 1525
AT 55

PB/PC 825

5

EC 650, 1225
EC/EB 825
SF 500, 650, 825 Brg, 1000
AT 115, 205

5.

Refer to Figure 8, Page 10. Set the input volt-
age selector switch SW1 for the AC input
being used.

6.

Refer to Figure 8, Page 10. Set switches

SW2 and SW4 in accordance with either of

the following:

If local torque adjust potentiometers are

used, set to “up” position.

If external or remote torque adjust poten-
tiometers are wired to the control, set to
“down” position. Refer to Figure 9 below.
Input/Output signal Relationships, when
makingthe settings required in steps 7 -
10. Circuit logic is diagrammed here for
your convenience.

7.

Proper operating mode setting (switch SW3)
depends on how the control inputs are wired:

Set SW3 in the “up” position for level
input operation from a single switching
device. Channel 2 input controls output
switching when the control is operated in
this mode.

Set switch SW3 in the “down” position for
pulse input mode operation. This requires
input switching on both Channel 1 and
Channel 2 inputs.

8.

Overexcitation Set-up

Switch SW5 controls the overexcitation pulse

to Channel 1 while switch SW6 controls the
overexcitation to Channel 2. to enable the
OEX, set the switch in the “down” position for
the channel to be overexcited. The “up”
positions disable the OEX pulses.

Channel

Input

(See Note 1)

Channel 1 Input

Inhibit

Channel 2

Input

Channel 2 Input

Inhibit

Auxiliary

Input

(See Note 2)

Output Inhibit

Input

Channel 2 Override

Input

Channel 1

Output

Channel 2

Output

Off

Off

On

On

2 Inputs/Channel 1 & 2

Full On
Not Adj.

On
Adj.

C


Channel 2
Input

Channel 2
Input Inhibit

Auxiliary
Input
(See Note)

Output Inhibit
Input

Channel 2
Override
Input

Channel 1
Output

Channel 2
Output

Notes:

1. Channel 1 input signal can be configured by

SW10 to provide same function with inverted
signal.

2. Auxiliary input shown configured as a Channel 1

input, can be configured by SW11 to provide
same operation as a Channel 2 input.

3. Diagram reflects current flow through optically-

isolated control inputs in either sourcing or
sinking made.

4. See set-up switches on back cover.

Notes:

1. Auxiliary input shown configures as a Channel 2

input. Auxiliary input non-functional if configured
as a Channel 1 input when control is configured
for a singal input from Channel 2.

2. Diagram reflects current flow through optically-

isolated control inputs in either sourcing or
sinking mode.

3. See set-up switches on back cover.