Symptom D: Magnet or field on channel 1 does not disengage when input is switched

Probable Cause

Solution

Channel 2 override input activated

Check status of channel 2 override, and release if

activated.

Faulty control

Replace main control logic board.

Symptom E: Magnets or fields do not appear to have enough torque

Probable Cause

Solution

Dip switches improperly set

Check dip switch settings per chart found on page 9 and
reset if necessary.

Magnets or fields incorrectly wired

Check wiring between control and magnets or fields.
Require if necessary.

Torque adjust potentiometers set too low

Check setting of torque adjust potentiometers and

increase if required.

Clutches or brakes incorrectly sized

Verify proper size by repeating sizing process in Warner
Electric Master Catalog, form P-137.

Symptom F: Outputs don’t switch; inputs don’t switch

Probable Cause

Solution

Input incorrectly wired

Check for proper wiring schemes and Require if necessary.

Faulty switching device

Check for proper operation and replace if defective.

Control switches on main board not set

Check positions of switches on main board and reset for

properly

proper configuration.

Faulty control

Replace main control logic board.

Replacement Parts

CBC-750-6

Complete Control Less Cover

6041-448-001

Main Control Logic Board Assembly

6041-101-001

Cover

6041-101-001

Fuse F1

458-8001-074

Fuse F2

458-8001-010

CBC-750-24

Complete Control Less Cover

6041-448-002

Main Control Logic Board Assembly

6041-101-002

Cover

6041-101-004

Fuse F1

458-8001-074

Fuse F2

458-8001-028

CBC-750-90

Complete Control Less Cover

6041-448-003

Main control Logic Board Assembly

6041-101-003

Cover

6041-101-004

Fuse F1

458-8001-074

Fuse F2

458-8001-026