Warner Electric Electrically Released Motor Brake Module for EM-MBFB and EUM-MBFB User Manual

Page 3

Advertising
background image

3

Warner Electric • 800-825-9050

P-1337 • 819-0314

24 Volt Brake recommended controls are:

CBC-500-24, 24-30 VAC input

part no. 6024-448-002

CBC-550-24, 120/220/240/380/480 VAC input

part no. 6024-448-005

All Permanent Magnet type

Electrically Released Brake Modules are
polarity sensitive. See the service installation
sheet included with the control for connection
information.

Burnishing and Maintenance

No burnishing required, units are pre-burnished at
factory.

As with any friction-type device, some initial
concern should be given to wear rate.

Improper voltage setting can reduce the braking
life. Once the best release voltage has been
established, precautions should be taken to
prevent machine operators, or other personnel not
familiar with wear characteristics, from changing
the potentiometer setting arbitrarily.

To reach the normal wearing components, reverse
the installation procedure for the module assembly.

Wear Pattern

Wear grooves appear on the friction surfaces. This
is a normal wear condition, and does not impair
functioning of the unit. Never machine the friction
surfaces to remove grooves or score marks
resulting from normal wear.

Heat

Excessive heat and high operating temperatures
are causes of rapid wear. Units, therefore, should
be ventilated as efficiently as possible, especially if
the application requires fast, repetitive cycle
operation.

Step 2: Electrical Connections

The conduit hole in the motor brake is threaded
for standard pipe conduit connectors. The wiring
diagram included with each Warner Electric control
shows the proper electrical connections to be made.
Note: Controls used must have adjustable
output voltage.

Connect the red wire from the unit to the “+”
terminal of the DC supply and the black wire from
the unit to the “-” terminal of the DC supply.

Note: Refer to the brake release adjustment
process on page 4.

Control Requirements

All Permanent Magnet Type Electrically Released
Brake Modules are polarity sensitive. Therefore, the
(+) red wire must be connected to the (+) terminal
and the (-) black wire to the (-) terminal.

Potentiometer control will then provide adjustment
for the proper brake release point as described in
the “brake release” procedure.

See the service installation instruction provided with
controls for connection information.

90 Volt Brake recommended controls are:

*CBC-160-1 120 VAC input

part no. 6013-448-001

*CBC-160-2 220-240 VAC input

part no. 6013-448-002

CBC-200

120 VAC input
part no. 6011-448-001

CBC-300

120 VAC input
part no. 6021-448-001

CBC-500-90 120 VAC input

part no. 6024-448-003

CBC-550-90 120/220/240/380/480 VAC input

part no. 6024-448-006

*These controls are for use with conduit box kit
part no. 5370-101-042. All others require other
enclosures or alternate mounting.