Warner Electric Electrically Released Motor Brake Module for EM-MBFB and EUM-MBFB User Manual

Page 5

Advertising
background image

5

Warner Electric • 800-825-9050

P-1337 • 819-0314

6. With the armature re-engaged, slowly

reduce the applied voltage until the armature
disengages from the magnet. Note and record
the applied voltage at this point.

7. The optimum release point for the brake is

half-way between the two recorded voltage
readings. Adjust the supply to this optimum
release voltage.

Note: The above procedure should be done by
visually watching the armature move and may
be repeated if necessary from Step 1 through
Step 7.

If any problems should occur during adjustments or
application questions arise, please contact Technical
Support at 1-800-825-9050 Monday through Friday
7:30 a.m. - 4:30 p.m. central time.

Notes: Visit Warner Electric’s website at
www.warnerelectric.com for dimensional
drawings, weights, inertias and a complete
offering of our products including clutches, brakes,
and clutch or brake controls and service parts.

In addition, Warner Electric module products,
controls and service parts information can be found
in our catalog P-1234-WE. Call 815-389-3771 to
request any of our catalogs.

Advertising