Note: Warner Electric Tension brakes are not
polarity sensitive, so wiring between
terminals on the MCS2000-DRV2 and
brake are not sensitive to the + and
- designations.
The following 24 volt tension brakes can be
used with the MCS2000-DRV2 Driver for 48 volt
operation with overcurrent feature.
ATT Series
MTB Series
Magnetic Particle
ATTB/ATTC-25
ATTB/ATTC-55
ATTB/ATTC-115
All MTB’s up to 12
magnets
* Up to 16 magnets if
outputs paralleled
MPB/MPC2
MPB/MPC15
MPB/MPC70
MPB/MPC120
MPB240
POB/POC-0.3 to 20’s
PRB-H’s 1.2 to 20’s
PTB’s 2.5 to 20’s
PMC-A’s 10 to 40’s
PHC-R 0.6 to 40’s
*POB/POC-40 & 80 if output
and inputs paralleled
Figure 5 48 Volt System Power Supply and Brake Wiring
48 Volt DC Power Supply
MCS2000-PSDRV2 Driver
* When 16 magnet MTB Brakes and POB/POC-40 and 80 Magnetic
Particle Brakes are used, inputs and outputs must be wired parallel to
obtain sufficient output current for proper brake operation.