Warner Electric MCS2000-PSDRV2 User Manual

Page 18

Advertising
background image

18

Warner Electric • 800-825-9050

P-2010-7 • 819-0525

The following chart shows a comparison of the MCS2000-PSDRV, MSC2000-PSDRVH and the
MCS2000-PSDRV2 terminal connections.

LED’s

Green

Green

Red

Red

LED Operation

OFF

OFF

ON

ON

ON

Functional Description

Internal installation error at power up.
Fault Error. Output locked “OFF”,
Driver has tripped.
Return MCS2000-PSDRV2 for Repair.

0.5 Sec ON/0.5 Sec OFF

1.5 Sec ON/0.5 Sec OFF

Short Circuit or Overload on Output at
Power Up. Output Locked “OFF”, Driver
has tripped.
Reset by Power Off and then Power On.

Short Circuit or Overload during normal
operation. Output Locked “OFF”. Driver
has tripped.
Reset by Power Off and then Power On.

Internal auxiliary power supply out of
tolerance. Output Locked “OFF”.
Auto Reset when condition clears.

Internal auxiliary power supply failure or
drive power supply greater than 48 VDC,
+10%. Output Locked “OFF”.
Auto Reset when condition clears.

OR

Figure 7 LED Indicator Operations and Descriptions – Fault Conditions