Note: Warner Electric Tension brakes are not
polarity sensitive, so wiring between terminals on
the MCS2000-DRV2 and brake are not sensitive to
the + and - designations.

The following 24 volt tension brakes can be used
with the MCS2000-DRV2 Driver for 48 volt operation
with overcurrent feature.

ATT Series

ATTB/ATTC-25
ATTB/ATTC-55

ATTB/ATTC-115

MTB Series

All MTB’s up to

12 magnets

*Up to 16 magnets

if outputs paralleled

and inputs

paralleled

Magnetic Particle

MPB/MPC2

MPB/MPC15
MPB/MPC70

MPB/MPC120

MPB240

POB/POC-0.3 TO 20’S

PRB-H’S 1.2 TO 20’S

PTB’S 2.5 TO 20’S

PMC-A’S 10 TO 40’S

PHC-R 0.6 TO 40’S

*POB/POC-40 & 80

if output and

inputs paralleled

Warner Electric • 800-825-9050

P-2010-6 • 819-0524

Brake

Brake

“A”

“B”

48 Volt

Power
Supply

- DC
+DC

MSC2000-DRV2

“A” Antiresidual

Channel A

“B” Antiresidual

Channel B

1. In A 0-10V

2. 0V

3. In B 0-10V

4. 0V

5. Brk A+

6. Brk A-

7. Brk B+

8. Brk B-

9. -DC Power

10. + 24 - 48 VDC

48 Volt DC Power supply

MCS2000-DRV2 Driver

Figure 5

* When 16 magnet MTB Brakes and POB/POC-40 and 80 Magnetic Particle Brakes are used, inputs and
outputs must be wired parallel to obtain sufficient out put current for proper brake operation.

48 Volt System Power Supply and Brake Wiring