Warner Electric MCS2000-DRV2 User Manual

Page 6

Advertising
background image

Wiring to the MCS2000-CTDA or
MCS2000-CTLC Controllers

Note: Since the MCS2000-CTDA and
MCS2000-CTLC controllers have 25 pin DB
connectors with cables, wiring is made via
the cable.

Care must be taken to insure

the correct wires are connected and none
of the other wires contact or short out. It is
recommended that unused wires be cut
off and taped so that shorting and grounding
out does not occur.

Note: Refer to the MCS2000-CTDA or
MCS2000-CTLC Manual for exact wire
functions and designations.

Refer to Figure 3 for wiring hook-ups.

AR “A”

AR “B”

1. In A 0-10V

2. 0V

3. In B 0-10V

4. 0V

5. Brk A+

6. Brk A-

7. Brk B+

8. Brk B-

9. -DC Power

10. + 24 - 48 VDC

(green)

(red)

(red)

(red)

(green)

(green)

Figure 2

MSCS2000-ECA to MCS2000-DRV2

MCS2000-ECA Controller

MCS2000-DRV2 Driver

Note: Wiring is shown for both channels. If only one channel is required, then follow wiring
shown for channel “A” only.

Warner Electric • 800-825-9050

P-2010-6 • 819-0524

6