Ensity, Fmt xx, Density – ADIC FastStor Mass Storage Device User Manual

Page 43

Advertising
background image

Operation and Maintenance

27

Mode 5 –

DENSITY

Mode 5 is used to set the density format of the data cartridge tape. All previously unformatted DLTtape III, DLTtape IIIXT, and
DLTtape IV data cartridges can be formatted to the densities shown in the following table.

Drive Model

Data Cartridge Cartridge Density

(native mode)

Cartridge Density
(compressed mode)

DLT 4000

DLTtape III
DLTtape IIIXT
DLTtape IV

2.6, 6.0, 10.0 GB
15.0 GB
20.0 GB

20.0 GB
30.0 GB
40.0 GB

DLT 7000

DLTtape III
DLTtape IIIXT
DLTtape IV

2.6, 6.0, 10.0 GB
15.0 GB
20.0, 35.0 GB

20.0 GB
30.0 GB
40.0, 70.0 GB

DLT 8000

DLTtape III
DLTtape IIIXT
DLTtape IV

2.6, 6.0, 10.0 GB
15.0 GB
20.0, 35.0, 40.0 GB

20.0 GB
30.0 GB
40.0, 70.0, 80.0 GB

Maximum Capacity

Notes

The density menu can only be used with a tape loaded in the drive.

The density of previously recorded DLT data cartridges cannot be changed unless the tape is reformatted which will result

in all data being lost.

The default density of unformatted data cartridges is dependent upon the drive installed in your FastStor, and the type of

tape being used.

To access Mode 5, press the MODE button until the LCD appears as shown:

ensity

1 2

3

4 5 6 7

Press the SELECT button to select Mode 5. The LCD will appear as shown (XX is the lowest native density selectable for

this cartridge):

Fmt XX

1 2

3

4 5 6 7

Press the NEXT or PREVIOUS button to scroll through the density choices. Press SELECT when the desired density setting

is displayed. When your FastStor has completed the command, it will return to the LdR REAdY.