Oven service procedures – XLT XD-9006A (GAS Oven Version – C, AVI Hood Version – B) User Manual

Page 24

Advertising
background image

24

Technical Support US: 888-443-2751

Technical Support INTL: 316-943-2751

W/C

mbar

kPa

W/C

mbar

kPa

3.5

8.75

0.875

10

25

2.5

0.2

0.49

0.049

0.2

0.49

0.049

All Oven Models

Natural Gas

LP Gas

Low Flame Bias

High Flame Bias

Figure 5

Check Low Bias Pressure:

Pull one of the two blue wires going into the modulating valve. (This simulates a temperature
drop and allows the oven to run at low flame bias)

(NOTE if the flame goes out turn the 5mm screw clockwise 1 turn to increase low flame bias)

Wait 30 seconds and the oven will re-light.

Using a 5mm socket turn the Low Flame Bias screw (Figure 6) until desired setting is
achieved. Use (Figure 5) for correct valve settings.

Figure 6

5 mm

OVEN SERVICE PROCEDURES

Multi-Valve Adjustment Procedure

Advertising