3 esd protection, 4 reference schematic, Figure 4-32: tv out schematic reference – IEI Integration ICE-DB-9S User Manual

Page 83

Advertising
background image

ICE Module

Page 70

4.10.2.3 ESD Protection

ESD clamp diodes are required for each TV-DAC channel. These low capacitance

clamp diodes should be placed as near as possible to the TV-Out connector on the

COM Express carrier board between +5V supply voltage and ground.

4.10.2.4 Reference Schematic

At least 30 mils of spacing should be used for the routing between each TV-DAC

channel to prevent crosstalk between the TV-DAC signals. The maximum trace length

distance of the TV-DAC signals between the COM Express connector and the 150Ω

±1% termination resistor should be within 12 inches. This distance should be routed

with a 50 Ω trace impedance.

TV_DAC_C

3

TV_DAC_B

3

TV_DAC_A

3

TV_AGREEN_Y

C133

3.3P_4_N_50V

2

1

TV_ABLUE_CVBS

C132

3.3P_4_N_50V

2

1

R168

150_4_1%

L9

FB150_6_200MA

+V3.3

D7

BAV99LT1G_SOT23

A

C

K

C129

3.3P_4_N_50V

2

1

+V3.3

D8

BAV99LT1G_SOT23

A

C

K

C128

3.3P_4_N_50V

2

1

R169

150_4_1%

TV_ARED_C

R170

150_4_1%

+V3.3

L10

FB150_6_200MA

D6

BAV99LT1G_SOT23

A

C

K

L11

FB150_6_200MA

C131

3.3P_4_N_50V

2

1

C130

3.3P_4_N_50V

2

1

TV_ABLUE_CVBS

TV_AGREEN_Y

TV_ARED_C

TV1

HEADER_2X3_2.54

GND

1

Y

2

GND

3

C

4

GND

5

CVBS

6

Figure 4-32: TV Out Schematic Reference