Alto-Shaam AR-6G User Manual

Page 13

Advertising
background image

AR-6G Rotisserie Operation & Care Manual • 11

I n s t a l l a t I o n

AR-6G Rotisserie Operation & Care Manual • 11

G a s c o n n e c t I o n s

This gas appliance has been set to operate with either

natural gas or propane as indicated on the identification

name plate. Make certain the gas supply matches the

nameplate information. Should conversion to the opposite

fuel be desired, conversion parts must be ordered from

the factory. Conversion must be completed by a qualified

service person only. Always remember to reflect the

conversion on the nameplate.

Gas specIfIcatIons

NATURAL GAS PROPANE GAS

AR-6G

195,000 Btu/hr.

195,000 Btu/hr.

InstallatIon reQUIrements

GAS CONNECTION: 3/4" NPT

CHECK PLUMBING CODES FOR PROPER SUPPLY

LINE SIZING TO ATTAIN MINIMUM BURNER

MANIFOLD PRESSURE SHOWN:

NATURAL GAS: 5" W.C.

PROPANE GAS: 10" W.C.

MAXIMUM INLET PRESSURE: 14" W.C.

NOTE: If a flexible gas line is used, it must be AGA

approved, commercial type and at least 3/4" I.D.

HOOD INSTALLATION IS REQUIRED

GAS VALVE MAY REQUIRE FIELD ADJUSTMENT

ABOVE 3,250' (991m)

AND IS NOT ADJUSTED AT THE FACTORY.

Gas pressUre chart

The appliance has been factory adjusted according to the

gas type specified on the identification name plate.

technIcal specIfIcatIons

Natural Gas

Min. Connected

Pressure

7.0" W.C.

1.12 kPa

Max. Connected

Pressure

14.0" W.C.

3.5 kPa

Propane Gas

Min. Connected

Pressure

11.0" W.C.

1.99 kPa

Max. Connected

Pressure

14.0" W.C.

3.5 kPa

D a n G e r

CONNECTING TO THE WRONG GAS
SUPPLY COULD RESULT IN FIRE OR
AN EXPLOSION CAUSING SEVERE
INJURY AND PROPERTY DAMAGE.

c a U t I o n

RESIDENTIAl GAS CONNECTIONS
AND hARD-pIpED GAS CONNECTIONS
DO NOT MEET NSF CERTIFICATIONS

W a r n I n G

TO AVOID SERIOUS PERSONAL
INJURY, installation of this appliance
must conform to local, state, and
national codes; the current edition
of the American National Standard
Z223.1, National Fuel Gas Code, and
all local municipal building codes.
In Canada, installation must be in
accordance with Standard CAN/CSA
B 149.1 and Installation Codes - Gas
Burning Appliances, and local codes.

Advertising