STEP 6: CPU CARD INSTALLATION

To install the CPU card please follow the instructions below.

Step 1:

Remove the slot cover at the back of the chassis. To do
this, remove the slot cover retention screw at the top of
the slot cover.

Figure 9: Remove the Slot Cover Retention Screw

Step 2:

Slide the CPU card into the socket on the backplane
reserved for the CPU card. If you are installing a full
size CPU card, make sure the back edge of the CPU
card slots into the corresponding plastic guide rail
located behind the cooling fans.

Figure 10: Slide the CPU Card into the Sockets

Step 3:

To secure the CPU card, reinsert the previously
removed slot cover retention screw.

STEP 7: PCI/ISA EXPANSION CARD
INSTALLATION

The RACK-360G supports up to 14 PCI/ISA expansion cards and
the RACK-305GATX variant supports up to 7 expansion cards. To
install an expansion card (PCI or ISA) please follow the steps below.

Step 1:

Remove the slot cover at the back of the chassis. To do
this, remove the slot cover retention screw at the top of
the slot cover.

Step 2:

Slide the PCI/ISA expansion card into reserved
PCI/ISA socket on the backplane.

Step 3:

To secure the PCI/ISA expansion card, reinsert the
previously removed slot cover retention screw.

STEP 8: DISK DRIVES INSTALLATION

The RACK-305G chassis has two drive brackets: one main drive
bracket and a side bracket. The main drive bracket supports up to
three 5.25” optical drives or two 5.25” drives and one 3.5” drive
(HDD or FDD). The side bracket supports one 3.5” FDD drive.
To install the drives, please follow the steps outlined in the sections
below.

S

TEP

8.1: R

EMOVE THE

S

IDE

B

RACKET

Before any drives can be installed, the side bracket attached to the
main drive bracket must be removed. To remove the side bracket,
remove the two retention screws from the top of the side bracket that
secure the side bracket to the main bracket.

Figure 11: Remove the Side Bracket

S

TEP

8.2: I

NSTALL

3.5”

D

RIVES INTO THE

S

IDE

B

RACKET

The side bracket supports one 3.5” FDD. If you want to install a 3.5”
FDD drive into the side bracket, please follow the steps below.

Step 1:

Remove the front flap from the side bracket by
removing the two retention screws that secure the front
flap to the side bracket.

Step 2:

Place a 3.5” FDD drive into the bracket. Make sure the
FDD PCB board is facing the surface of the bracket
and the 4-pin power connector and the IDE/SATA
interface connector are facing the rear of the bracket.

Step 3:

To secure the 3.5” FDD to the side bracket, insert four
retention screws.

S

TEP

8.3: R

EMOVE THE

M

AIN

D

RIVE

B

RACKET

If you wish to install 5.25” optical drives or more than one 3.5” drive
(HDD or FDD), the main drive bracket must be removed. To remove
the main drive bracket from the chassis, follow the steps below.

Step 1:

Remove the side bracket. See Step 8.1: Remove the
Side Bracket above.

Step 2:

Remove the four retention screws that secure the main
bracket to the base of the chassis.

Advertising