Installation, Caution – Lincoln Electric IM10042 RANGER 305 G User Manual

Page 17

Advertising
background image

A-10

INSTALLATION

RANGER® 305G

A-10

7. Set the "IDLE" switch to the "AUTO" position.

When not welding, the RANGER® 305G engine
will be at the low idle speed. If you are using an
LN-25 with an internal contactor, the electrode is
not energized until the gun trigger is closed.

8. When the gun trigger is closed, the current sens-

ing circuit will cause the RANGER® 305G engine
to go to the high idle speed, the wire will begin to
feed and the welding process started. When weld-
ing is stopped, the engine will revert to low idle
speed after approximately 12 seconds unless
welding is resumed.

If you are using an LN-25 without an internal con-
tactor, the electrode will be energized when the
RANGER® 305G is started.

------------------------------------------------------------------------

Connection of LN-742,K487-25 Spool Gun, and
Cobramatic to RANGER® 305G

1. Shut the welder off.

2. Connect per instructions on the appropriate con-

nection diagram in Section F.

CAUTION