PrEVENtiVE mAiNtENANCE CHECkLiSt

Check

Daily

Weekly 50 Hrs.

500

Hrs.

1500

Hrs.

3000

Hrs.

Clean Filters

X

Water leaks

X

Descale Pump

X

X

Cam & bearing

X

X

Seal Change

X

X

Valve Change

X

X

trOUBLESHOOtiNg CHArt

SymPtOm

POSSiBLE CAUSE(S)

correctIVe ActIoN

no water flow

1. Tank is empty or water is not turned on

1. Fill tank or turn on water supply

2. Filter clogged

2. Clean filter

3. Pump valves clogged or damaged

3. Examine valves and clean or replace

4. Pump has lost prime

4. Follow priming procedure

Low pressure

1. Worn nozzle

1. Replace nozzle with new one of same
size

2. leak in high pressure hose or connections

2. Check hose and connections

3. Filter clogged

3. Clean filter

4. Pump valves clogged or damaged

4. Examine valves and clean or replace

Pump pulsates when spraying

1. Filter clogged

1. Clean filter

2. Pump valves clogged or damaged

2. Examine valves and clean or replace

Motor does not operate

1. blown fuse or circuit breaker

1. Replace circuit breaker or fuse. Check circuit

for wire damage or component damage

leaks seen under pump

1. Worn pump seals

1. Replace with new plunger and seals

2. Abrasives in solution have damaged pump

seals

2. Mix chemical thoroughly and improve filter

Regulator leaks fluid from cap

1. Pressure is set too low

1. Set pressure higher to keep internals from

moving too much
2. Replace seal