Pressure washer, Assembly operating information, Connect to electrical supply – Pumptec PRESSURE WASHER User Manual

Page 4

Advertising
background image

4

Version 110112

Pumptec Operating Instructions and Parts Manual

PRESSURE WASHER

positive displacement pumps providing a specific amount of

fluid constantly while operating. This volume of fluid must

be directed out thru a nozzle or back to a tank because it

cannot be stopped completely without creating excessively

high pressure and risk of damage to pump, components,

property and person. It is recommended a safety device such

as a regulating valve be installed directly on pump head as

protection in case of a failure of another component. Pressure

switches can be used to automate pump operation, but they

must have a pressure regulating device installed as a safety

device.
Fluid can enter a pump either from a filtered tank or

pressurized fluid line.
It is common to use a tank with pumps that are mounted above

the pump. Filtration is important to maintain proper function

of the pump and system. The extent of filtration may be greater

based upon some uses such as misting with ultra-fine nozzles.

ASSEMBlY OPERATIng InFORMATIOn

Circuit Breaker

w/ Auto Restart

Circuit Breaker

w/ Auto Restart

Master On/Off Switch

Quick Connect on

Inlet Side of Unloader

Unloader

Adjustment Knob

Quick Connect on

Outlet Side of Unloader

Inlet Garden Hose

Swivel Nut

Pulse Hose

PN 80390

no on/off switch or circuit breaker provided

PN 80729

1. Check water supply. Is there water in tank? Is the garden

hose “on” ?

2. Check for leaks.
3. Check line Strainer, Clean?

4. Disconnect coupler on inlet side of unloader, direct hose

back to tank or onto ground away from motor

Start pump and allow air to purge from system (5 -15

seconds)

Stop pump and reconnect bypass hose to inlet side of

unloader

5. Connect discharge hose to outlet side of unloader
Connect spray gun assembly to other end of hose assembly
6. If you have a variable nozzle, adjust nozzle to low pressure

mode . ( click to forward position)

Click forward

(away from gun)

for low pressure

Rotate to

Change

Spray Angle

Click backward

(toward the gun)

for low pressure

HI

LOW

0

80

!

!

7. If you have separate nozzles with quick connects remove

nozzle from spray gun

8. Unscrew knob on unloader 4-6 turns to adjust to low

pressure setting

9. Hold trigger open on spray gun and start pump
Allow all air in system to purge
Stop pump
Adjust variable nozzle to high pressure (pull nozzle back

toward gun)

-OR-
Install quick connect high pressure nozzle
10. Restart Motor and squeeze spray gun trigger and adjust

spray angle to appropriate position.

gradually increase pressure by adjusting unloader knob
Adjust pressure to suitable pressure for the specific cleaning

task.

nOTE: Higher pressure requires more amperage. Do not

unnecessarily overload the system. This could result in the

premature failure of the motor and void your warranty.

COnnECT TO ElECTRICAl SUPPlY

nOTE: 12 Volt pumping systems are unique in that “problems”

are most likely to be electrical. If the pump motor is running

and no water is coming out of the pump - you have a pump

Advertising