D

Troubleshooting

97

If you experience problems while operating your QS, please use the

following table to check for possible causes and solutions before

contacting Alesis customer service for assistance.

Symptoms

Cause

Solution

The display does not light up when

the ON/OFF switch is turned on.

No power.

Check that the power cable is

plugged in properly.

No sound.

Bad Connections.

Check your audio cables; if

necessary, swap cables.

Volume is turned down.

Raise the [VOLUME] slider or

Pedal 1.

Keyboard Mode is set incorrectly.

Set the Keyboard Mode to

NORMAL (Global Parameter

page 6)

Switch QS from Mix Mode to

Program Mode or vice versa to

reset the MIDI Volume.

External MIDI device sent

Volume (CC#7) or Expression

(CC#11) commands with a value

approaching 0.

Re-transmit higher values from

MIDI device.

Trying to record onto a track

higher than the current Song

allows.

Copy all tracks, and paste into a

new song defined as having more

tracks.

INPUT SELECT is set to 2, 4, 8,

or 12-input mode.

Reset INPUT SELECT for 24-

input mode.

MIDI input in Mix mode

isn’t working (i.e., you can’t control

your unit via MIDI from a

sequencer or some other

controller).

EDIT PREVIEW plays back only

tracks selected for editing.

To hear all tracks, deselect any

tracks selected for editing using

TRACK EDIT.

Sustain pedal was plugged in after

power was turned on.

Turn the unit’s power off, wait a

moment, and then turn it on again.

Notes sustain continuously.

Stuck notes due to incomplete

MIDI data.

Switch QS from Mix Mode to

Program Mode or vice versa.

Disable MIDI echo/Thru on

external MIDI device

Notes played from QS have a

“doubled” or “flanged” sound

MIDI echo/Thru enabled on

external MIDI device or computer

Put QS into Out 01 mode (Global

Mode, page 6)

Mod Wheel not working well (or

at all)

Unit was re-initialized with Mod

Wheel up

Put Mod Wheel all the way down

and re-initialize

LCD shows “ADDRESS

ERROR”

Bad Sys-ex data sent to QS via

MIDI input

Re-initialize. If it persists, load in

known good bank.

Advertising