OnePower Line Interactive UPS (EN)

A03-PS651 Pag. 23

function to computer peripherals

3

PHONE JACK: Protect the Fax/Modem/Tel from lightning
and spike disturb.

4

POWER SWITCH: UPS turn on/off button.

5

LED:

• NORMAL (AC input display): AC in right power

supply mode, display NORMAL icon, AC in
wrong power supply mode, conceal NORMAL
icon.

• BATTERY: AC is abnormal, display when in

battery back-up model, otherwise, no display

• UNUSUAL (Abnormal indication) When UPS is

short circuit, overload, abnormal control circuit,
and intermittent time of re-start UPS is less than 6
seconds under battery mode, display UNUSUAL

6

INPUT CIRCUIT BREAKER: Protects against UPS system
overload

7

COMMUNICATION INTERFACE PORT: Connect to the
computer with the communication RS232 cable.

8

UTILITY POWER INPUT LINE: Connects to input utility
power through the input power cord

1.10 Buzzer Explanation

Buzzer Meaning:

• When UPS is operating in normal utility power range, buzzer emits no

sound

• When Utility power is abnormal, and UPS is in battery mode, Buzzer

emits sound for every 5 seconds.

• When Utility power is abnormal, and UPS is in battery mode. But the

battery is low voltage, Buzzer emits sound for every 1 seconds.

• When UPS is overload or short circuit, Buzzer emits continuous sound.


1.11 Replacing the Battery

The Following Precautions Should be Observed When Working on Batteries:

• Remove watches, rings, or other metal objects.
• Use tools with insulated handles.