LB-9501 : PLC 2 status (SN1, COM2), set on to retry connection
LB-9502 : PLC 2 status (SN2, COM2), set on to retry connection
LB-9503 : PLC 2 status (SN3, COM2), set on to retry connection
LB-9504 : PLC 2 status (SN4, COM2), set on to retry connection
LB-9505 : PLC 2 status (SN5, COM2), set on to retry connection
LB-9506 : PLC 2 status (SN6, COM2), set on to retry connection
LB-9507 : PLC 2 status (SN7, COM2), set on to retry connection
LB-9800 : PLC 3 status (SN0, COM3), set on to retry connection
LB-9801 : PLC 3 status (SN1, COM3), set on to retry connection
LB-9802 : PLC 3 status (SN2, COM3), set on to retry connection
LB-9803 : PLC 3 status (SN3, COM3), set on to retry connection
LB-9804 : PLC 3 status (SN4, COM3), set on to retry connection
LB-9805 : PLC 3 status (SN5, COM3), set on to retry connection
LB-9806 : PLC 3 status (SN6, COM3), set on to retry connection
LB-9807 : PLC 3 status (SN7, COM3), set on to retry connection
LB-10069 : forced to reconnect remote printer/backup server when IP changed on-line (set ON)
LB-10070 : forced to reconnect PLC 4 (Ethernet) when IP or system parameters changed on-line
(set ON)
LB-10071 : forced to reconnect PLC 5 (Ethernet) when IP or system parameters changed on-line
(set ON)
LB-10072 : forced to reconnect PLC 6 (Ethernet) when IP or system parameters changed on-line
(set ON)
LB-10073 : forced to reconnect PLC 7 (Ethernet) when IP or system parameters changed on-line
(set ON)
LB-10074 : forced to reconnect PLC 8 (Ethernet) when IP or system parameters changed on-line
(set ON)
LB-10075 : forced to reconnect PLC 9 (Ethernet) when IP or system parameters changed on-line
(set ON)
LB-10100 : PLC 4 status (Ethernet), set on to retry connection
LB-10400 : PLC 5 status (Ethernet), set on to retry connection
LB-10700 : PLC 6 status (Ethernet), set on to retry connection
LB-11000 : PLC 7 status (Ethernet), set on to retry connection
LB-11300 : PLC 8 status (Ethernet), set on to retry connection
LB-11600 : PLC 9 status (Ethernet), set on to retry connection
LB-11900 : PLC 10 status (Ethernet), set on to retry connection
LB-11901 : PLC 11 status (Ethernet), set on to retry connection
LB-11902 : PLC 12 status (Ethernet), set on to retry connection
LB-11903 : PLC 13 status (Ethernet), set on to retry connection
LB-11904 : PLC 14 status (Ethernet), set on to retry connection
LB-11905 : PLC 15 status (Ethernet), set on to retry connection
LB-11906 : PLC 16 status (Ethernet), set on to retry connection
LB-11940 : delete the earliest event log file on SD card (set ON)
LB-11941 : delete all event log files on SD card (set ON)
LB-11942 : refresh event log information on SD card (set ON)
LB-11943 : delete the earliest event log file on USB disk (set ON)
LB-11944 : delete all event log files on USB disk (set ON)
LB-11945 : refresh event log information on USB disk (set ON)
LB-11946 : reserved
LB-11947 : reserved
LB-11948 : reserved