1 general specifications, 1 electrical specifications, 2 environmental specifications – Proface AGP3500 - 10.4 DIO HMI" User Manual

Page 31: 1 general specifications -2, General specifications, 2 2.1 general specifications, Electrical specifications, Environmental specifications

Advertising
background image

GP3000H Series Hardware Manual

2-2

2.1

General Specifications

2.1.1

Electrical Specifications

2.1.2

Environmental Specifications

Power Supp

ly

Input Voltage

DC24V

Rated Voltage

DC19.2 to 28.8V

Allowable Voltage Drop

10 ms (max.)

Power Consumption

16.7 W (max.)

In-Rush Current

60 A (max.)

Half width (Time duration with a current exceeding 30 A):

40 µs max.

Voltage Endurance

AC500V 20 mA for 1 minute

(between charging and FG terminals)

Insulation Resistance

DC500V 10 MΩ (min.)

(between charging and FG terminals)

Physical

Ambient Operating

Temperature

0 to 40°C

Storage Temperature

-20 to +60°C

Ambient Humidity

10 to 90% RH

(Wet bulb temperature: 39°C max. - no condensation.)

Storage Humidity

10 to 90% RH

(Wet bulb temperature: 39°C max. - no condensation.)

Dust

0.1 mg/m

3

and below (non-conductive levels)

Pollution Degree

For use in Pollution Degree 2 environment

Atmosphere

Free of corrosive gases

Air Pressure Vibration

Resistance (altitude

range)

800 to 1,114hPa

(2000 meters above sea-level maximum)

Mechanical

Vibration Resistance

IEC/EN61131-2 compliant

5 to 9 Hz single-amplitude 3.5 mm [0.14 in.]

9 to 150 Hz constant-accelerated velocity 9.8 m/s

2

X,Y,Z directions for 10 cycle (100 minute)

Concussion Resistance

IEC/EN61131-2 compliant

(147 m/s

2

X,Y,Z directions for 3 time)

Drop Resistance

IEC61131-2 compliant

1.0 meter drop - 2 times.

Electrical

Noise Immunity

Noise Voltage: 1,000 V

P-P

Pulse Duration: 1 µs

Rise Time: 1 ns

(via noise simulator)

Electrostatic Discharge

Immunity

6 kV (complies with IEC/EN 61000-4-2 Level 3)