Proface AGP3500 - 10.4 DIO HMI" User Manual

Page 7

Advertising
background image

7

Name

Description

A LED

B Latch Button

Bracket that secures the CANopen Master Unit to the
LT.

C Extension Connector

Connect the extension connector to the AUX unit
interface/expansion unit (EXT2) at the rear side of the
LT.

D CANopen Interface

CANopen Slaves Interface

LED Color Status

Description

PWR Green

ON

Power is on.

OFF

Power is OFF.

RUN Green

Blinks once per
second.

Communication
STOPPED state.

Blinks three
times and then
blinks again
three times after
1 second has
elapsed.

Initialization is in
progress.

ON

Normal
Communication
State.

ERR Red

OFF

Normal
Communication
State.

Blinks once per
second.

Communication
data error

Blinks twice and
then blinks again
twice after 1
second has
elapsed

Check the node ID
and baud rates of
the connection
devices.

ON

The connected
device is not
connected to the
bus. (BUS OFF)

Blinking

The node ID
address or
communication
settings are invalid.