PS-3710A Series Hardware Manual

3-2

3.1

Installation • Uninstallation

3.1.1

Installation

This section describes the procedures and precautions for installing the PS-A units.

„ Check the Installation Gasket’s Seating

It is strongly recommended that you use the installation gasket, since it absorbs vibration in addition to

repelling water.

For the procedure for attaching the installation gasket, refer to “4.4 Replacing the Installation Gasket”.

„ Creating a Panel Cut

Create the correct sized opening required to install the PS-A, using the installation dimensions given.

Determine the panel thickness according to the panel thickness range with due consideration of panel strength.

SEE

“4.4 Replacing the Installation Gasket” (page 4-4)

• Before installing the PS-A into a cabinet or panel, check that the installation

gasket is securely attached to the unit.

• A gasket which has been used for a long period of time may have scratches or

dirt on it, and could have lost much of its dust and drip resistance. Be sure to

change the gasket periodically (or when scratches or dirt become visible).

SEE

PS-3710A Series

„

Panel Cut Dimensions” (page 2-21)

Check that the installation panel or cabinet’s surface is flat, in good condition and has no

jagged edges.

Even if panel thickness is within recommend range for "Panel Cut Dimensions", the panel

could warp, depending on panel's material and installation location of PS-A or other

devices. To prevent panel warpage, the installation surface may need to be strengthened.

Panel thickness area