11

*1

If the Conductor

s end (individual)

wires are not twisted correctly, the
end wires may either short
against each other, or against an
electrode.

„ Power connector specification

• Kind of power cord is FKC 2,5/3-STF-5,08

which are Phoenix Contact products.

Use the following wiring for FP. Those are
Phoenix Contact products.

„ Connecting the Power Cord

When connecting the AC type power cord,

be sure to follow the procedures given

below.

(1) Confirm that the power cord is

unplugged from the power supply.

(2) Push the Opening button by a small and

flat screw driver to open the desired pin
hole.

(3) Insert each pin terminal into its each

hole. Release the Opening button to
clamp the pin place.

(4) After inserting all three pins, insert the

Power Plug into the Power Connector at
FP. Fix the plug with two(2) minus
screws.

• The torque required to tighten these

screws is 0.5 to 0.6N

•m.

• To prevent the possibility of a terminal

short, use a pin terminal that has an
insulating sleeve.

Using the USB Cable Clamp

„ USB Cable Clamp Attachment Pro-

cedure

‹ Installation to USB cable

(1) Connect the USB cable to the connector.

(2) Insert the cable clamp into the cable

clamp holder as shown in the following
figure, and tighten the clamp until the
cable is secured in place.

L

AC Input Terminal-
live line

N

AC Input Terminal-
neutral line

FG

Ground Terminal
connected to the
FP chassis

Recommended
Drivers

SZS 0.6X3.5 (1205053)

Recommended
stick end
terminal

AI 0.75-10GY(3201288)
AI 1-10RD(3200182)
AI 1.5-10BK(3200195)
AI 2.5-12BU(3200962)

Crimp tool for
recommended
stick end
terminal

CRIMPFOX ZA 3
(1201882)

FG

N

L

Power
Cable
Joint

AC power supply cord

Opening Button

L
N

FG

USB cable clamp

USB Cable

Stopper

USB cable clamp holder