2 mxlogger operation guide, Flow of operations during installation, 2 mxlogger operation guide -4 – Yokogawa DAQWORX User Manual

Page 11: Flow of operations during installation -4, 2 mxlogger operaton gude, Flow of operatons durng installaton

Advertising
background image

1-4

IM WX103-01E

1.2

MXLOGGER Operaton Gude

Flow of Operatons durng Installaton

The figure below shows the general flow of operation when the MX100 is installed

initially.

Wire the input/

output modules

Operations on the MX100

Operations on the PC

Connect the

network cable

Connect the power

cord

Turn ON the power

switch

Set up the

MXLOGGER

Set the network

parameters of the PC

Start the

logger

Search the MX100/

configure the network

Configure the system

Set the data

acquisition condition

Set the measurement

conditions/set

the computation

Acquire/Monitor the data

and monitor the alarm

Change the display

conditions

Record the data

Install the MX100

See the Installation
and Connection Guide.

Section 2.1

Section 2.2

Section 2.3

Sections 2.4 and 2.5

Section 2.10

Section 2.10

Section 2.12

Section 3.4

Start the

Viewer

Display the recorded

data

Perform statistical

computation over an

area of data

Read values using

cursors

Convert the data

format

Print the displayed

data

Sections 3.1 and 3.2

Section 3.3

Section 3.7

Section 3.8

Section 1.5

Section 1.5

Section X.X indicates the referred

sections in this manual.

*The available digital

(DO) outputs are alarm

output, manual DO, fail

output, and error output.

The Installation and Connection Guide (IM
MX100-72E)

is an abridged manual provided with

the MX100 main module. The Installation and
Connection Guide

does not explain all the

functions and operations. It also does not cover the

details of the precautions and limitations of usage.

For a detailed explanation, see the MX100 Data
Acquisition Unit User's Manual (IM MX100-01E)
contained in the manual CD-ROM.

See the DAQWORX Installation
and Operation Guide (IM
WX1000-01E).

Set the appropriate IP address,

subnet mask, and default

gateway of the PC.

Search all connected MX100s and

configure the network parameters

such as the IP address of the

connected MX100s.

Select the MX100 to be connected,

select the acquisition interval of

each input module, etc.

Select the acquisition interval to be

used, select the record interval, set

record start/stop conditions, etc.

Set the transmission

output

Section 2.8

Set analog/PWM output and others

Set the alarm

Section 2.6

Set the alarm

See section 2.7 for digital output*

settings.

Set up events

Section 2.9

Set individual events

Set the input mode,

measurement range,

measurement span, etc.