If pressure increases to a preset level, the TX200 will again start to recover refrigerant.
The Compressor will turn on and the Compressor-On Light will illuminate.

Allow this sequence to repeat until the Compressor-On Light remains off continuously for
at least 2 minutes.

The DEEP VACUUM Switch can be pressed to draw a deeper vacuum if so desired.

Push bottom of Main Power Switch to turn TX200 OFF.

WARNING...

DO NOT RECOVER FROM THE LIQUID SIDE OF AN A/C
SYSTEM WITH A CAPACITY OF MORE THAN 20 LBS.
UNLESS THE DOT CYLINDER ON THE INLET SIDE OF
THE UNIT IS MONITORED FOR TOTAL WEIGHT.

REFER TO THE LIQUID CAPACITY OF THE CYLINDER
AND DO NOT FILL BEYOND 80% OF THAT RATING.

USE A SCALE TO MONITOR THE WEIGHT.

OIL DRAIN & MEASURE (Automotive Only)

When the TX200 is used to recover refrigerant, it may be desirable to drain and measure
the oil removed during the recovery process.

Disconnect hoses from the DOT Cylinder, invert the cylinder, and open the VAPOR Valve.
Let the Oil drain into the measuring cup provided. Opening the LIQUID Valve will speed
the draining process by equalizing pressure in the cylinder.

Unless the A/C System had previously been overfilled, the TX200 will typically not remove
enough oil to make replenishment necessary.