Cable Gland & Supply Cord Fitting Instructions (Single phase)
RG3300, RG5000

The cable gland assembly Fig. 10 (items 1 & 2) provides the necessary protection

against ingress of solid objects and moisture as well as providing cable retention.

Assembly instructions are as follows: -
1. Ensure selected cable sheath

diameter is within the permitted

range (6.5 to 9.5 mm).

2. Strip and prepare the cable

sheath and insulators as

shown in Fig. 8.

3. Disassemble cable gland as

shown in Fig. 10 and insert

cable into position

ensuring ‘O’-ring (item 1) is

placed over the cable before

the clamping insert (item 2) is tightened.

4. Consolidate the stranded conductor

ends by twisting and shape the earth

conductor as shown in Fig. 9 (item 3).

5. Remove earth terminal post clamping

components and assemble as shown

in Fig. 9 ensuring shaped conductor

is orientated as shown and all strands

of the conductor are clamped between

the

washers.

6. Insert and secure live and neutral

conductors ensuring all conductor

strands are clamped.

7. Confirm cable routing is as

shown in Fig. 10 and

assemble

and

secure terminal box lid.

12

110

E

N

L

80

70

8

8

1

2

3

Fig. 8

Fig. 9

Fig. 10