Specifications – STI HK3 User Manual

Page 3

Advertising
background image

3

Polycarbonate Cleaning Instructions

Rinse with water to remove abrasive dust and dirt. Wash with soap or mild detergent, using a soft cloth.
Rinse once more, then dry with a soft cloth or chamois. Exercise caution when using water inside enclo-
sure. Make sure unit is completely dry inside before reassembling. Do not use razor blades.

Specifications

Polycarbonate Enclosure

Flammability

UL94 V-2

Wall Thickness

back box: .20 inches (5.1mm)
cover: .12 inches (3.1mm)

NEMA Rating

3R

Warranty

Lifetime against breakage in
normal use.

Silicone Laminate Heater

STI-1200A-HTR 110 VAC 50/60 Hz

UL Recognized Component

STI-1200-A-HTR240 240 VAC 50/60 Hz UL Recognized Component

100 Watts

Life: @ -10˚C (14˚F) ~ 70˚C (158˚F)

5 Years

Duty Cycle: -40˚F (-40˚C)

16%

-70˚F (-57˚C)

38%

-99˚F (-73˚C)

100%

Fan

24 VDC (±10%), 90 mA

UL Recognized Component

Life

5 Years Continuous Duty

WARNING: The polarity of the circulating fan is important as it only
rotates in one direction with red lead being positive.

MISE EN GARDE: La polarité du ventilateur de circulation est importante car
il ne tourne que dans un sens avec son fil rouge étant celui du pôle positif.

Gasket

Material

Neoprene

Life

5 Years

PART #

HEIGHT

WIDTH

DEPTH

Internal Dimensions

(158mm)

(104mm)

(31mm)

1200A-HTR

6.25 in.

4.125 in.

1.25 in.

1200A-HTR240

Advertising