Description:

This system contains a STI-6400 with a DPDT key switch

to be mounted on one side of a door or wall; and a

similar looking housing, also with a DPDT key switch,

but without an alarm for the opposite side of the door.

An authorized person with a key can disable the alarm

on either side of the door. When disabled, and LED will

illuminate, and the door can be opened without setting

off the alarm. After passing through the door, the

alarm can be armed again from the opposite side.

Installation:

1. Follow

STI-6400

mounting instructions and set

switches to the desired positions for alarm timing

and volume.

2. For straight through door or wall installation, mark

the center of the 5/16 inch hole in the mounted

base, then remove the base from the door or wall.

3. Drill a 5/16 inch diameter hole through the door or

wall at the marked location.

4. Align the same diameter hole in the secondary unit

base to the back side of the door or wall and

mount.

5. Route the wire from the STI-6400 unit through the

hole and into the secondary unit.

6. Attach the 6 wires to the terminal block pins 2 thru

7 matching wire colors on the terminal block label.

7. Seal the hole around the wires with an effective

fire stop material, if required.

8. Attach the battery in the secondary unit and install

the cover.

9. Cycle the key switch to be sure the LED’s turn “ON”

and “OFF”. Leave the LED’s “ON” until ready to test

the alarm.

10. Attach the battery to the STI-6400 and install the

cover.

11. Close the door and test.

Operation:

1.

With the door closed, turn either key switch to arm
the alarm. The LED’s on both sides of the door

should turn “OFF”.

2.

If the door is opened while the LED’s are “OFF”,
then the alarm will sound according to the switch

settings of the STI-6400.

3.

To reset the alarm, turn either key to the opposite
position (the LED’s will turn “ON”), close the door

and turn either key switch again (the LED’s will turn

“OFF”).

4.

When the system is armed, authorized passage can
be accomplished by turning either key switch until

the LED’s turn “ON”, and remove key. The door can

now be opened without sounding the alarm. When

passage is complete, close the door, turn the key

switch (the LED’s will turn “OFF”). The door alarm

is once again armed.

Addendum for STI-6406 with Dual Access Control