Multi-Service IronWare Multicast Configuration Guide

11

53-1003032-02

Support for Multicast Multi-VRF

1

Support for Multicast Multi-VRF

Multicast Multi-VRF support for the Brocade device includes the following:

Static Mroute – As described in

“Configuring a static multicast route within a VRF”

you can

configure static multicast route from within a specified VRF.

PIM (PIM-SM and PIM-DM) – The procedure for configuring PIM within a VRF instance is
described in

“Enabling PIM for a specified VRF”

and

“Enabling PIM Sparse for a specified VRF”

.

DVMRP – The procedure for configuring DVMRP within a VRF instance is described in

“Enabling DVMRP for a specified VRF”

.

System max parameter changes

Several changes to the system max commands have been made in support of Multicast Multi-VRF.
That includes retiring the following system max commands:

system-max multicast-route

system-max dvmrp-mcache

system-max dvmrp-route

system-max pim-mcache

system-max igmp-max-group-address

These commands which require a system reload to take effect have been replaced by the following
runtime commands:

ip max-mroute – This command replaces the system-max multicast-route command.

max-mcache – This command described in

“Defining the maximum number of DVMRP cache

entries”

replaces the system-max dvmrp-mcache command.

max-mroute – This command described in

“Defining the maximum number of DVMRP routes”

replaces the system-max dvmrp-route command.

max-mcache – This command described in

“Defining the maximum number of PIM cache

entries”

replaces the system-max pim-mcache command.

ip igmp max-group-address – This command described in

“Defining the maximum number of

IGMP group addresses”

replaces the system-max igmp-max-group-address command.

NOTE

If the deprecated system-max commands are used, the new runtime commands will be substituted
in the running config.

Additionally, you can set a maximum value for multicast VRF CAM entries as described in

“Defining

the maximum number of multicast VRF CAM entries”

.

Show and clear command support

The following show and clear commands have been introduced or enhanced to support Multicast
Multi-VRF:

“clear ip dvmrp [vrf vrf-name] cache”