Provider bridge brocade2 – Brocade Multi-Service IronWare Administration Guide (Supporting R05.6.00) User Manual

Page 185

Advertising
background image

Multi-Service IronWare Administration Guide

167

53-1003028-02

CFM monitoring and show commands

6

Brocade1(config-cfm)#domain-name CUST_1 level 5

6. Create a maintenance association within a specified ESI Site1vlan30, and a vlan-id 30 with a

priority 3.

Brocade1(config-cfm-md-CUST_1)#ma-name ma_5 esi Site1vlan30 vlan-id 30

priority 3

7. Set the time interval between successive Continuity Check Messages to 10-seconds.

Brocade1(config-cfm-md-CUST_1-ma-ma_5)#ccm-interval 10-second

8. Configuring a MED for each of the Domain Service Access Points of a service instance creates

a MA to monitor the connectivity. Add ethernet port 1/2 as MEP to a specified maintenance
association.

Brocade1(config-cfm-md-CUST_1-ma-ma_5)#mep 4 up port ethe 1/2

9. To configure the hostname as Brocade1, enter a command such as the following.

Brocade1(config)#hostname Brocade1

10. Configure interface ethernet 1/1 as the provider network by entering the following commands.

Brocade1(config)#interface ethernet 1/1

Brocade1(config-if-e10000-1/1)#port-type provider-network

Brocade1(config-if-e10000-1/1)enable

Brocade1(config-if-e10000-1/1)end

11. Configure interface ethernet 1/2 as the customer-edge by entering the following commands.

Brocade1(config)#interface ethernet 1/2

Brocade1(config-if-e10000-1/2)#port-type custonmer-edge

Brocade1(config-if-e10000-1/2)enable

Brocade1(config-if-e10000-1/2)end

12. Configure interface ethernet 1/3 as the provider network by entering the following commands.

Brocade1(config)#interface ethernet 1/3

Brocade1(config-if-e10000-1/3)#port-type provider-network

Brocade1(config-if-e10000-1/3)enable

Brocade1(config-if-e10000-1/3)end

Provider Bridge Brocade2

1. Create the port-based VLAN300 that contains the tagged interfaces that you want to use by

entering the following commands.

Brocade2(config)# vlan300

Brocade2(config-vlan-300)# tagged ethe 1/1 ethe 1/3

2. To enable CFM, enter the following command.

Brocade2(config)#cfm-enable

3. Create a maintenance domain with a specified name CUST_1 and level 5.

Brocade2(config-cfm)#domain-name CUST_1 level 5

4. Create a maintenance association within a specified ESI Site2vlan30, and a vlan-id 30 with a

priority 3.

Brocade2(config-cfm-md-CUST_1)#ma-name ma_5 esi Site2vlan30 vlan-id 30

priority 3

5. Set the time interval between successive Continuity Check Messages to 10-seconds.

Advertising