Brocade Multi-Service IronWare Administration Guide (Supporting R05.6.00) User Manual

Page 396

Advertising
background image

378

Multi-Service IronWare Administration Guide

53-1003028-02

Syslog messages

A

Notification

Session DOWN for RSVP session session-id
Reason Administratively Down

The BFD session for the RSVP session
specified by the session-id is Down for
Administrative reasons.
The form of the session-id displayed is
IPv4 tunnel endpoint or tunnel ID or
extended tunnel ID.
For example 10.22.22.2/3/11/11/11/1

Notification

Session UP for RSVP session session-id

The BFD session for the RSVP session
specified by the session-id is Up.
The form of the session-id displayed is
IPv4 tunnel endpoint or tunnel ID or
extended tunnel ID.
For example 10.22.22.2/3/11/11/11/1

Notification

Transceiver type checking has been
enabled!

The transceiver type checking feature has
been re-enabled. The feature is enabled by
default and does not send the message
under normal circumstances. However, if it
is disabled and then re-enabled the device
will send this message.

Warning

Optic is not Brocade qualified (port) Type
type-description
Vendor vendor-name, Version version-num
Part# part-no,
Serial# serial-no

The optic module installed in the Interface
module at the port specified by the port
variable is not Brocade qualified although
the port is still operational. The Type,
Vendor, Version, Part#, and Serial # of the
optic module is provided.

Alert

Optic is not Brocade qualified, optical
monitoring is not supported (port)
Type type-description
Vendor vendor-name, Version version-num
Part# part-no,
Serial#serial-no

The optic module installed in the Interface
module at the port specified by the port
variable is not Brocade qualified and will
not be able to be monitored using the
Optical Monitoring function. The Type,
Vendor, Version, Part#, and Serial # of the
optic module is provided.

Alert

Optic is not capable of optical monitoring
(port)
Type type-description
Vendor vendor-name, Version version-num
Part# part-no,
Serial# serial-no

The optic module installed in the Interface
module at the port specified by the port
variable is not able to be monitored using
the Optical Monitoring function. The Type,
Vendor, Version, Part#, and Serial # of the
optic module is provided.

Alert

Incompatible optical trans-receiver
detected on port n

Indicates that in incompatible XFP or SFP
has been installed in the port specified. A
port with an incompatible optical module
installed are shut down.

TABLE 85

Syslog messages Optics (Continued)

Message level

Message

Explanation

Advertising